Replacing The Mechanical Valve (Optional Replacement Table) - JUKI KE-3010 Maintenance Manual

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

9-1-1. Replacing the Mechanical Valve (Optional Replacement Table)

1) Turn OFF the compressed air to the machine main unit.
2) Disconnect the air tubes from the elbow union.
3) Remove the mounting screws to detach the valve from the bracket.
4) Attach the elbow union and silencer on a new valve and secure them to the bracket with the
mounting screws.
5) Turn ON the compressed air to the machine main unit.
6) When the mechanical valve for the drive cylinder up/down that is mounted on the support
cylinder on the FL and RR sides for the M and L specifications has been replaced, adjust the
position so that the lever of the mechanical valve is pushed to move up the drive cylinder as
the mechanical cart is set.
<M and L Specifications>
FL side/RR side
(Common specifications)
Mounting screw
PV010505000
MECHANICAL
VALVE
40094341
BANK_VALVE_BRACKET
FL side/RR Side Support Cylinder
(Mechanical/electric replacement
table specifications)
40094341
BANK_VALVE_BRACKET
Figure 9-1-1-1 Roller Lever (M, L)
Maintenance Guide
Mounting
screw
PV010505100
MECHANICAL
VALVE
Adjust the mounting position so that the lever is
pushed to move up the drive cylinder when the
mechanical cart is set.
9-3
FL side/RR side
(Common specifications)
Mounting screw
PV010505000
MECHANICAL
VALVE
40094341
BANK_VALVE_BRACKET
Rev. 2.0