13-4-2-3 Changing the Coplanarity CPU Settings
1) Turn ON the power to the mounter.
2) Put the mounter in a status that only Windows is running.
Open [Control Panel] from the [Start] menu.
3) Select [Network Connections] in the "Control Panel" dialog box.
4) The "Network Connections" dialog box will appear.
Right-click [Local Area Connection] to select [Properties].
DANGER
Maintenance Guide
Do not change [Local Area Connection 2]. [Local Area Connection 2]
is the network settings for the communication between the
coplanarity sensor and coplanarity CPU board. If these settings are
changed, the coplanarity measurement cannot be performed.
If the settings of [Local Area Connection 2] have been changed,
return the settings to the values shown below.
IP address
Subnet mask
13-46
: 192.168.0.100
: 255.255.255.0