Adjusting the feeder float sensor inside the mecha/machine
1) Set the NF12 at the left, center, and right positions of the bank. Open and close the front
cover to check that the sensor is turned OFF.
Figure 12-2-1 Adjusting the Feeder Float Sensor
Figure 12-2-2 Adjusting the Feeder Float Sensor
∗
If the sensor is not turned OFF even though the font cover is opened, the sensor mounting
position may deviate in the Y-direction.
If this occurs, loosen the sensor mounting screws and move the sensor back and forth.
2) Put the NF16N in the same manner as described for step 1) to check that the sensor is
turned OFF.
∗
If the sensor is not turned OFF even though the font cover is opened, the sensor mounting
position may deviate in the Y-direction. If this occurs, loosen the sensor mounting screws and
move the sensor back and forth. (Normally, move the sensor toward the transport side.)
Maintenance Guide
cover
Front
NF12 feeder
NF16N feeder
Move the sensor back and forth.
Light
emission
12-9
(Transport side)
Light
receiving
Rev. 2.0