Placement Monitor (Optional); Replacing The Lnc61/62 - JUKI KE-3010 Maintenance Manual

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

DANGER

[22] PLACEMENT MONITOR (OPTIONAL)

22-1. Replacing the LNC61/62

The LNC61 is used when the optional placement monitor for the KE-3010 is mounted while the
LNC62 is used when the placement monitor for the KE-3020V/3020VR is mounted.
When the LNC61/62 has been replaced, it is necessary to input the laser related MS parameters
again. (For details, see section 2-7.)
<Procedure>
1) Disconnect the connectors (encoder and IEEE1394) and remove the mounting screws
and
(3 pcs.) to detach the LCN61.
2) Mount a new LCN61 in the reverse order of disassembly.
∗ Before mounting a new LCN61/62, remove the Loctite solidified on the sensor bracket as
much as possible.
∗ Before mounting the sensor, put the sensor pin in the positioning hole in the bracket and
secure it after positioning.
∗ After the Loctite 242 has been applied to the sensor mounting screws
with a tightening torque of 2.6 Nm.
∗ After replaced, clean the laser window of the LNC61/62 with a clean cloth rag.
SL6041492TN
Maintenance Guide
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
EPV61/62
LNC61/62
Figure 22-1-1
22-1
Rev. 2.0
and
, secure them
Connectors
(2 pcs.)
SL6041402TN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-3020vKe-3020vr

Table of Contents