4. Setting the operation panel

4-1. Setting input/output of the ports

In order to use the cassette clamping function, input/output of the ports have to be set.
For the input/output settings of the ports, the following settings have been factory-set as default values.
If you have not changed the aforementioned settings, input/output setting of the ports is not necessary.
If you have changed the settings, set the ports as shown in the table given below. Refer to
the ports" p.12
or to the Engineer's Manual for the input/output settings of the ports.
Terminal
IN/OUT
name
IN
IOP04
IOP05
IOP06
IOP07
OUT
OOP04
OOP05

4-2. To use the cassette clamp

Set the memory switch K193 "One-touch utility clamp type" to "Type 1".
Refer to the Engineer's Manual for how to select the memory switch Kxxx (level 2).
Connector
number
CN43-18
5:Cassette clamp, clamp check L
CN43-19
7:Cassette clamp, clamp check R
CN43-20
4:Cassette clamp, cassette detection L
CN43-21
6:Cassette clamp, cassette detection R
CN55-8
4:Cassette clamp, clamp locking
CN55-10
5:Cassette clamp, clamp release
Table 1: Input/output settings of the ports
– 10 –
Function number
Item
Without
Not use
Type 1
Cassette clamp is used
Type 2
Automatic clamp is used
"4-4. Setting
Active level
LOW
LOW
LOW
LOW
LOW
LOW