3) Detach the CONTACT SUB UNIT to be replaced.
40101989
CONTACT SUB UNIT
SL6030592TN
SCREW M3 L=5
(2 locations each)
4) Disconnect the cables that have been connected to the CONTACT SUB UNIT using the nuts,
and then connect them to a new CONTACT SUB UNIT. (Tightening torque, 0.4N・m)
(Check using a multi-meter that the cable is not in contact with the counter electrode side.
The positive (+) side, negative (−) side, and CVS unit need to be insulated.)
(Front)
PCB cables
Check the insulation status using a
multi-meter after the connector that
connects the cables and PCB has
been disconnected.
Maintenance Guide
+ side
− side
19-2
(Rear)
Probe cables
WS0310002KN
SPRING WASHER M3
NM6030001SC
NUT M3
Rev. 2.0