JUKI KE-3010 Maintenance Manual page 37

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

7)
Check the operation of the +X-limit sensor (X positive limit sensor). Manually move the head
right to a position where it interrupts the light to the +X-limit sensor.
8)
Check that the "X-axis movement limit" dialog box pops up on the monitor.
9)
Move the head left to reset the +X-limit sensor.
10) After resetting, perform the same operation as described in step 3) to turn ON the main
circuit power and close the "X-axis movement limit" dialog box.
1-3-3-2. Checking the Y-Limit Sensor Operation
1)
In the same manner as described for the section, Checking the X-limit sensor operation,
check the operation of the Y-limit sensor.
2)
After the operations of both the X- and Y-sensors have been checked completely, exit the
main unit software and set the safety direction setup to "No".
3)
When the machine is ready to power OFF, turn OFF the POWER switch.
4)
Turn ON the POWER switch again.
Maintenance Guide
1-26
Rev. 2.0