4) When the light unit is detached, the camera can be seen. Remove three M4×20 SEMS cap
bolts (SL6042092TN) to detach the camera.
5) Clean the camera mounting surface with alcohol.
6) In the reverse order of steps described above, return a new camera and light unit to their
original positions.
7) When inserting the camera cable, insert it with the
front.
Maintenance Guide
Never remove this screw since it has
been adjusted correctly at the factory.
40106751: S-VCS ST camera assembly
40106752: S-VCS OP camera assembly
Figure 8-1-2
Figure 8-1-3
8-2
mark on the connector faced toward the
Rev. 2.0