JUKI KE-3010 Maintenance Manual page 245

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

Adjusting the ETF incorrect insertion detection sensor (Front)
1) Insert/remove the ETF into/from the left, center, or right of the electric bank and move it
within a play of the rail to check whether or not the sensor is turned OFF.
∗ If the sensor is OFF (the green lamp is off), turn the volume to make the green lamp lit.
2) Place the ETF8S on the left, center, or right slide rail of the electric bank to check that the
sensor is turned OFF.
Adjusting the ETF incorrect insertion detection sensor (rear)
1) Check that the red light coming from the sensor is seen on the reflector (the red light does
not deviate from the reflector).
Green LED
2) Keep the Teaching button pressed for 2 sec. or longer. The auto adjustment of the light
quantity is then started. When the auto adjustment has been completed successfully, both
the green and orange LEDs will light up.
3) If one or both LEDs flash slowly immediately after teaching, it is thought that the red light
deviates from the reflector position. If this occurs, adjust the position again.
4) Insert/remove the ETF into/from the left, center, or right of the electric bank and move it
within a play of the rail to check whether or not the sensor is turned OFF.
5) Place the ETF8S on the left, center, or right slide rail of the electric bank to check that the
sensor is turned OFF.
Maintenance Guide
Teaching button
Orange LED
12-12
Rev. 2.0