5)
Check the operation of the X-near sensor. Check that the display item "X-Near" is OFF.
Manually move the head left to a position where it passes the near sensor.
6)
After the head has passed the near sensor, check that "X-Near" shown in the Figure above
is ON. Furthermore, visually check that the LED on the X-near sensor is lit.
7)
Check the operation of the Y-near sensor. Check that the display item "Y-Near" is OFF.
Manually move the head toward you to a position where it passes the near sensor.
8)
After the head has passed the near sensor, check that "Y-Near" is ON. Furthermore, visually
check that the LED on the Y-near sensor is lit.
9)
Exit the main unit software. When the machine is ready to power OFF, turn OFF the
POWER switch.
10) Turn ON the POWER switch again and perform the origin return.
Maintenance Guide
1-28
Rev. 2.0