(5) How to measure the sliding load of the X-axis
1) Move the HEAD_UNIT to the left.
2) Push the HEAD_UNIT from the left to the right repeatedly to measure the maximum value
three times, and then calculate the average value.
3) Push the HEAD_UNIT from the right to the left repeatedly to measure the maximum value
three times, and then calculate the average value.
(6) Check that the difference between the average value obtained in step (5)-2) and that
obtained in (5)-3) is 5 [N] or less.
Maintenance Guide
1-68
Rev. 2.0