JUKI KE-3010 Maintenance Manual page 334

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

The connection destination boards of other sensors are shown in Table 14-7-1-3 "Cable
Assemblies Connected to the BASE I/O Board" and Table 14-7-1-4 "Cable Assemblies
Connected to the Sensor Block ". Connect the sensors while referring to these figure and tables.
Table 14-7-1-3 Cable Assemblies Connected to the BASE I/O Board
Part No.
40110049 MTC MTS I/F CABLE ASM
40110049 MTC MTS I/F CABLE ASM
40110047 SMEMA IN CABLE ASM
40110048 SMEMA OUT CABLE ASM
40113658 LOAD CELL ANAROG CABLE ASM
−−−− −−−−−−−−−−−−−−−−
−−−− −−−−−−−−−−−−−−−−
40097608 FLUXER RELAY CABLE ASM
40110051 SB CABLE ASM
40110051 SB CABLE ASM
−−−− −−−−−−−−−−−−−−−−
−−−− −−−−−−−−−−−−−−−−
40110044 SV CABLE ASM
40110037
AWC DRIVE CABLE ASM
(40110038)
(AWC DRIVE CABLE ASM (EN))
40110030
BU DRIVE CABLE ASM
(40110031)
(BU DRIVE CABLE ASM (EN))
40110029 MT1-3 PULSE CABLE ASM
40110043 AWC ENC CABLE ASM
40110036 BU ENC CABLE ASM
40110018 BASE-IO PWR CABLE ASM
Maintenance Guide
Applicable cable
Part No.
14-37
CARRY board
connection
Part No.
destination
BASE01
CN1
BASE02
CN2
BASE03
CN3
BASE04
CN4
BASE05
CN5
CN6
−−−−
CN7
−−−−
BASE08
CN8
BASE09
CN9
BASE10
CN10
CN11
−−−−
CN12
−−−−
BASE13
CN13
BASE14
CN14
BASE15
CN15
BASE16
CN16
BASE17
CN17
BASE18
CN18
BC PWR
CN19
Rev. 2.0
Remarks
MTS I/F
MTC I/F
SMEMA LOWER
SMEMA UPPER
LOAD CELL (OP)
Not used
Not used
FLUXER (OP)
SENS POWER
SENS SIGNAL
Not used
Not used
SOLENOID VALVE
AWC (OP)
BU PULSE
IN, CNT, OUT DRIVER
AWC (OP)
BU ENC
PCB POWER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-3020vKe-3020vr

Table of Contents