X-Axis Magnescale Affixing Position - JUKI KE-3010 Maintenance Manual

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

1-2-1. X-Axis Magnescale Affixing Position

1)
With the X-axis magnescale affixing jig (40094362) put tightly in contact with the front of the
LM-guide and the bottom of the X-axis frame, make the magnescale in contact with the
X-axis magnescale affixing jig to affix the magnescale.
A marking-off line is provided at the affixing start position on the left when viewed from the
front.
Adjust the end face position of the magnescale to the marking-off line and affix the
magnescale.
Specification value: Magnescale affixing position (distance deviation in parallel to the
X_LM guide
L side of
machine
112.5±0.1(KE-3020V,VR)
59.5±0.1(KE-3010)
Figure 1-2-1-1 Magnescale Affixing Positions of M and L Board Specifications
X_LM guide
Cut
L side of
surface
machine
119±0.1(KE-3020V,VR)
71.5±0.1(KE-3010)
Figure 1-2-1-2 Magnescale Affixing Positions of X L Board Specifications
Maintenance Guide
head moving direction) ±0.1 mm
Cut
surface
Magnescale affixing position
and direction
181.5±0.1(KE-3020V,VR)
128.5±0.1(KE-3010)
Magnescale affixing
position and direction
188±0.1(KE-3020V,VR)
140.5±0.1(KE-3010)
1-9
Rev. 2.0
Center of Z-phase marking
Center of
Z-phase marking

Hide quick links: