1-3-2. Replacing the Y-Axis Limit Sensor and the Y-Axis Home Proximity Sensor

∗ If only the sensor is replaced, it is not necessary to adjust the position.
∗ If the sensor is replaced together with the bracket, it is necessary to adjust the position.
1)
Loosen the screws fixing the Y-limit sensor bracket and make the adjustment so that the
distances from the split pin mounting center position of the base frame are those shown in
the Figure below. After the adjustment has been completed, tighten the screws firmly. (See
Figure 1-3-2-1 (M and L board specifications) and Figure 1-3-2-2 (XL board specifications).)
<M and L board specifications>
Split pin
Viewed from A
Split pin hole part
Front side (Y negative limit sensor)
Front side 2 (Y near sensor)
Rear side 2 (Y ++ limit sensor)
Clearance between the limit sensor and the dog
Maintenance Guide
177
162
Figure 1-3-2-1 M and L Board Specifications
Distance from the split pin mounting center position on the front of the
base frame to the center of the sensor: 162 mm
Distance from the split pin mounting center position on the front of the
base frame to the center of the sensor: 177 mm
Distance from the split pin mounting center position on the rear of the
base frame to the center of the sensor: 67.5 mm
1.8 to 2.5 mm (target: 2.0 mm)
Y-limit sensor
1-21
Rev. 2.0
Split pin
Viewed from B
67.5
Split pin hole part