(3) Reciprocate the HEAD_UNIT several times until it is in contact with the X_STOPPER, and
then check that the movement is smooth. Measure the sliding load and check that the
measured value is 50[N] or less.
If the measured value does not satisfy the standard level, make the adjustment again from
step 1-8-4 (1).
(For details about how to measure the sliding load of the X-axis, see step 1-8-4 (5).)
(4) Apply the grease and move the HEAD_UNIT left and right to conform it to the entire shaft.
∗ Wipe off the oozed NSL grease with a cloth rag.
Maintenance Guide
∗ Put the top end of the push-pull gauge in contact with the
HEAD_PLATE and move the HEAD from the left to the right.
1-67
Put the top end of the push-pull gauge in
contact with this portion.
Rev. 2.0
HEAD_PLATE