Replacing The Ccd Camera And Lens - JUKI KE-3010 Maintenance Manual

High-speed chip shooter, high-speed flexible mounter
Table of Contents

Advertisement

4-2. Replacing the CCD Camera and Lens

1) Detach the camera assembly from the head plate using the procedure described in section
4-1, Replacing the OCC Assembly.
2) Remove the bolts
and lens.
3) Reassemble the components in the reverse order of disassembly.
(Apply Loctite 242 to the SEMS cap bolts
1.0N⋅m.)
4) After the CCD camera and lens have been replaced, adjust the focus and input the MS
parameters. (See 4-7, List of Readjustment Items After Replacement.)
SM6020302UZ
SEMS cap bolt
M2×3
SM6030602TN (×2)
Maintenance Guide
and
securing the CCD camera and lens to replace the CCD camera
OCC lens
Figure 4-2-1 CCD Camera/Lens
(×2), and then fix them with a tightening torque of
4-2
Rev. 2.0
CCD camera
SL6041292TN
SEMS cap bolt with
washer M4×12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-3020vKe-3020vr

Table of Contents