4-4. Replacing the Lens Filter/Light Diffuser
1) Detach the light assembly from the head plate using the procedure described in "Replacing
the OCC Assembly".
2) Remove the SEMS cap bolt
light filter U support, lens filter and guide plate.
3) Remove the countersunk-head screws
4) Reassemble the components in the reverse order of disassembly.
5) After the filter has been replaced, it is necessary to adjust the polarizing filter and OCC light.
(See 4-7, List of Readjustment Items After Replacement.)
Maintenance Guide
(×1), collar
Figure 4-4-1 Replacing the Lens Filter
(×1) and shoulder screws
(×4) to detach the lens filter.
SL6030892TN
SEMS cap bolt with washer M3×8
SM1030501SC
Countersunk-head screw M3×5
4-4
(×2) to detach the
40015847
OCC collar
E1038871000
Platen lock cam screw
40013949
Light filter U support
40043896
Lens filter
40013948
Guide plate
40043895
Light diffuser
Rev. 2.0