5) Adjust the sensor dog position
When opened:
When closed:
OPEN
sensor
Figure 7-1-3 When Opened
6) Connect a φ4 air tube.
Refer to the figure below, and connect the speed controller to the solenoid valve with an air
tube (φ4).
Figure 7-1-5 Air Piping and Speed Controller Positions
Maintenance Guide
Open the slide plate and secure the dog at a position where the dog is
further moved 1mm after the LED goes off.
Close the plate. The plate must be stopped at a position where it is further
moved 1mm after the LED is lit.
Sensor
dog
The sensor dog is
further moved 1mm left
after the LED goes off.
CLOSE
sensor
Figure 7-1-4 When Closed
Speed controller
Air tube φ4
Solenoid valve
7-3
Rev. 2.0
Sensor
dog
The sensor dog is
further moved 1mm right
after the LED lights up.