3) Disconnect all the connectors from the main
unit power supply unit.
When the optional coplanarity unit is mounted,
also detach the coplanarity power supply
assembly mounted next to the main unit power
supply unit.
4) Remove the round screws that secure the unit
and take out the main unit power supply unit
through the rear while carefully checking the
cables in the duct.
14-11-1-2. Detaching the ETF Power Supply Unit
1) Remove the hexagon screws that secure the ETF power supply unit.
2) Disconnect all the connector cables from the
ETF power supply unit and take out the unit.
Mount the power supply unit in the reverse order of disassembly.