Cycle Front Panel
Argument
Argument value
Channel Type
Device-Specific System
Value Type
Integer
Read/Write Mode
Write-Only
System Limits
Minimum: 1, Maximum: 60
Event Source
No
Description
This parameter causes the front panel LED of the specified device to cycle through its colors
(yellow-red-green-off) for the specified number of seconds.
NTP
Server—dev_ntp_server
Argument
Argument value
Channel Type
Device-Specific System
Value Type
String
Read/Write Mode
Read/Write
System Limits
Max String Length: 32
Default
pool.ntp.org
Event Source
No
Description
This parameter gets or sets the name of the network time protocol (NTP) server used to set the system time.
A power cycle is required for this parameter to take effect.