Polycom SoundStructure C16 Design Manual page 699

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Internal Temperature
Argument
Argument value
Channel Type
Device-Specific System
Value Type
List
Read/Write Mode
Read-Only
Values
ok : Normal operation
warning : Warning condition
error : Error condition
Event Source
Yes
Description
this parameter returns the temperature status of the specified device. If the internal temperature sensors
indicated the device is operating within a safe temperature rage, the ok value is returned. The warning value
is returned when the temperature is in the marginal temperature range. The error value is returned when
the temperature is in an unsafe temperature range.
Device
Type—dev_type
Argument
Argument value
Channel Type
Device-Specific System
Value Type
List
Read/Write Mode
Read-Only
Values
c16 : Conferencing 16x16
c12 : Conferencing 12x12
c8 : Conferencing 8x8
sr16 : Sound Reinforcement 16x16
sr12 : Sound Reinforcement 12x12
sr8 : Sound Reinforcement 8x8
Event Source
No
Description
This parameter returns the type of the device.
Polycom, Inc.
Status—dev_temp_status
699