Polycom SoundStructure C16 Design Manual page 678

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Automixer Hold
Time—am_hold_time
Argument
Argument value
Channel Type
Global Systems
Value Type
Integer
Read/Write Mode
Read/Write
Indices
1-63 : group number
Systems Limits
Minimum: 100, Maximum: 10000
Default
500
User Limits
No
Supported
Event Source
No
Description
This parameter defines how long (in ms) the microphone in the specified automixer group will be considered
active after the last detected significant level on the microphone.
Automixer Last Mic
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Boolean
Read/Write Mode
Read/Write
Phys Chans
Conferencing Mic/Line Input, Sound Reinforcement Mic/Line Input
Virt Chans
Mono, Stereo
Default
0
Event Source
No
Description
When this parameter is set to 1, the last mic mode is enabled on the microphone.
Polycom, Inc.
Mode—am_last_mic_mode
678