Connecting With The Ethernet Interface - Polycom SoundStructure C16 Design Manual

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

The following figure shows the RS-232 pin-out on the rear-panel of the SoundStructure device and
requirement for a straight-through cable for connection to an RS-232 port on a control system.
RS-232 Pin Out on SoundStructure System Rear Panel
Pin 5
Pin 1
Pin 9
Pin 6

Connecting with the Ethernet Interface

Each SoundStructure device has a rear-panel Ethernet interface for connecting to the local area network as
shown in the following figure. For systems that do not have authentication enabled, connect to the
SoundStructure device using port 52774 and telnet communication for systems. There is no administrative
login required to interface to SoundStructure devices over port 52774.
For systems that have authentication enabled (see
connect to the SoundStructure system using port 52775.
Ethernet Interface on SoundStructure System Rear Panel
LAN
C-LINK2
OBAM
IN
Polycom, Inc.
SoundStructure
Pin
Signal
1
--
2
TX
3
RX
4
--
5
Ground
6
--
7
CTS
8
RTS
9
--
PIN 2: TXD
PIN 3: RXD
PIN 5: GROUND
PIN 7: CTS
PIN 8: RTS
REMOTE CONTROL 1
RS-232
REMOTE CONTROL 2
IR
OUT
12V
LAN
Straight-through cable
Adding Authentication to SoundStructure
1
2
1
2
Control System
Pin
Signal
1
--
2
RX
3
TX
4
--
5
Ground
6
--
7
RTS
8
CTS
9
--
Systems),
534

Advertisement

Table of Contents
loading

This manual is also suitable for:

Soundstructure c8Soundstructure c12Soundstructure sr12

Table of Contents