Description
When the signal generator's sig_gen_type is set to sweep, the parameter sets the frequency (in Hz) at which
the sweep generator stops. The direction of the frequency sweep will be up or down depending on whether
the sig_gen_sweep_start parameter is higher or lower than this parameter.
Signal Generator Sweep
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read/Write
Phys Chans
Signal Generator
Virt Chans
Mono
System Limits
Minimum: 10, Maximum: 60000
Default
10000
User Limits
No
Supported
Event Source
No
Description
When the signal generator's sig_gen_type is set to sweep, this parameter sets the duration (in milliseconds)
that the sweep generator takes to sweep from its start frequency to its stop frequency.
Polycom, Inc.
Time—sig_gen_sweep_time
667