Drive Alarms - Siemens SINUMERIK 808D ADVANCED Diagnostic Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Definitions:
A PLC axis has not yet reached its end position and cannot be returned to a channel or neutralized. This alarm should
not occur when PLC data block FC18 is used.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Wait until the axis has reached the end position or terminate the movement with delete distance to go.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
3.3

Drive alarms

300402
System error in drive link. Error codes %1, %2
Parameters:
%1 = Error code 1
%2 = Error code 2
Definitions:
An internal software error or serious error condition has occurred, which could possibly be rectified by a hardware
reset.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Place a support request with the error text under: http://www.siemens.com/automation/support-request
Program
Switch control OFF - ON.
Continuation:
300406
Problem in the non-cyclic communication for basic address %1, additional information
%2, %3, %4
Definitions:
For PROFIdrive only:
A problem occured during the non-cyclic communication with the logical start address. The additional information
defines the location of the problem. If the logical start address 0 is output, only the additional information is relevant.
Reaction:
Alarm display.
Warning display.
Remedy:
Please inform the authorized personnel/service department. The alarm can be suppressed with MD11411
$MN_ENABLE_ALARM_MASK bit 1 = 0
Place a support request with the error text under: http://www.siemens.com/automation/support-request
Program
Clear alarm with the Delete key or NC START.
Continuation:
300410
Axis %1 drive %2 error when storing a file (%3, %4)
Parameters:
%1 = NC axis number
%2 = Drive number
%3 = Error code 1
%4 = Error code 2
Definitions:
An attempt to save a data block, e. g. the result of a measuring function, in the file system has failed.
On error code 1 == 291: An error occurred during preparation of the ACC information. Basic information prepared on
the drive contains an error or has an unknown format.
On error code 1 == 292: Memory shortage during preparation of the ACC information.
Reaction:
Interface signals are set.
Alarm display.
Diagnostics Manual