Fault
F30011: Line phase failure in
main circuit
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F30015: Phase failure motor
cable
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F30021: Ground fault
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
F30027: Precharging DC link
time monitoring
Reaction: OFF2
Acknowledgement:
IMMEDIATELY
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Cause
At the power unit, the DC link voltage ripple
has exceeded the permissible limit value.
Possible causes:
A line phase has failed.
The 3 line phases are inadmissibly
unsymmetrical.
The fuse of a phase of a main circuit
has ruptured.
A motor phase has failed.
A phase failure in the motor feeder cable
was detected.
The signal can also be output in the
following case:
The motor is correctly connected, however
the closed-speed control is instable and
therefore an oscillating torque is
generated.
Power unit has detected a ground fault.
Ground fault in the power cables.
Winding fault or ground fault at the
motor.
The power unit DC link was not able to
be pre-charged within the expected
time.
There is no line supply voltage
connected.
The line contactor/line side switch has
not been closed.
The line supply voltage is too low.
The pre-charging resistors are
overheated as there were too many
pre-charging operations per time unit
The pre-charging resistors are
overheated as the DC link capacitance
is too high.
The pre-charging resistors are
overheated.
The pre-charging resistors are
overheated as the line contactor was
closed during the DC link fast
discharge through the Braking Module.
The DC link has either a ground fault or
a short-circuit.
The pre-charging circuit is possibly
defective.
SINAMICS V70 alarms
5.2 Common faults and alarms
Remedy
Check the main circuit fuses.
Check whether a single-phase load is
distorting the line voltages.
Check the motor feeder cables.
Check the motor feeder cables.
Check the speed controller settings.
Check the power cable connections.
Check the motor.
Check the line supply voltage at the input
terminals.
447