Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 68

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
MD10718 $MN_M_NO_FCT_CYCLE_PAR contains an invalid array index of MD10715
$MN_M_NO_FCT_CYCLE[n]. Currently, the values 0 to 9 are permissible. The affected machine data is reset to the
default value -1. This deactivates the function.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function in MD10715 $MN_M_NO_FCT_CYCLE[n] that is not occupied by the system, or configure a
permissible array index in MD10718 $MN_M_NO_FCT_CYCLE_PAR.
Program
Switch control OFF - ON.
Continuation:
4152
Illegal configuration of the 'Block display with absolute values' function
Definitions:
The "Block display with absolute values" function has been illegally parameterized:
- An illegal block length has been set with MD28400 $MC_MM_ABSBLOCK:
While ramping up, the machine data will be checked for the following value range:
0, 1, 128 to 512
- An invalid display range has been set with MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[]. While ramping up,
the machine data will be checked for the following upper and lower limits:
0 <= MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8
0 <= MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= (MD28060 $MC_MM_IPO_BUFFER_SIZE +
MD28070$MC_MM_NUM_BLOCKS_IN_PREP).
Alarm 4152 is issued if the limits are violated.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure block length/display range within the permissible limits.
Program
Switch control OFF - ON.
Continuation:
4160
[Channel %1: ] Invalid M function number configured for spindle switchover
Parameters:
%1 = Channel number
Definitions:
An M function was specified in MD20094 $MC_SPIND_RIGID_TAPPING_M_NR in order to configure the M function
number for spindle switchover. The M function number is assigned by the system and cannot be used for the
switchover (M1 to M5, M17, M30, M40 to M45).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function which is not used by the system (M1 to M5, M17, M30, M40 to M45) in MD20094
$MC_SPIND_RIGID_TAPPING_M_NR.
Program
Switch control OFF - ON.
Continuation:
68