Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 96

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10204
[Channel %1: ] User action not possible without reference point (internal
action=%2<ALNX>)
Parameters:
%1 = Channel number
%2 = internal action number/internal action name
Definitions:
A specific user action is to be executed, which leads to a (possibly other) internal action, for which as least one axis
that needs to be referenced has not reached its reference point.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please reference the axis that needs to be referenced.
If the user action as an internal action leads to an NC start, whether or not the axis has to be referenced before NC
start can be decided via the channel-specific MD20700 $MC_REFP_NC_START_LOCK (NC start without reference
point). If the user action as internal actions leads to a user ASUB start, whether or not the axis has to be referenced
before ASUB start can be decided via the channel-specific MD20115 $MC_IGNORE_REFP_LOCK_ASUP (ASUB
start without reference point). If the user action as internal actions leads to a Prog Event start, whether or not the axis
has to be referenced before Prog Event start can be decided via the channel-specific MD20105
$MC_PROG_EVENT_IGN_REFP_LOCK (Prog Event start without reference point).
Channel or axis-specific referencing can be triggered.
Please inform the authorized personnel/service department. Whether or not the axis has to be referenced before NC
start can be determined via the channel-specific MD20700: $MC_REFP_NC_START_LOCK (NC start without
reference point). Channel or axis-specific referencing can be triggered.
Channel-specific reference point approach: The rising edge of the NC/PLC interface signal DB3200 DBX1.0 (activate
referencing) starts an automatic sequence, which starts the axes of the channel in the same sequence as specified in
the axis-specific MD34110 $MA_REFP_CYCLE_NR (axis sequence channel-specific referencing). 0: The axis does
not participate in channel-specific referencing, but it must be referenced for NC start, -1: The axis does not participate
in channel-specific referencing, but it need not be referenced for NC start, 1- 8: Starting sequence for the channel-
specific referencing (simultaneous start at the same no.), 1- 31: CPU type
Axis-specific referencing: Press the direction key that corresponds to the approach direction in the axis-specific
MD34010 $MA_REFP_CAM_MDIR_IS_MINUS (reference point approach in minus direction).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10208
[Channel %1: ] Continue program with NC start
Parameters:
%1 = Channel number
Definitions:
After block search with calculation, the control is in the desired state. The program can now be started with NC Start
or the state can be changed for the time being with overstore/jog.
Reaction:
Interpreter stop
Alarm display.
NC Stop on alarm.
Remedy:
Press NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10209
[Channel %1: ] Internal NC stop after block search
Parameters:
%1 = Channel number
Definitions:
Internal alarm which only initiates the alarm response NC Stop.
The alarm is output in the following situations:
- If MD11450 $MN_SEARCH_RUN_MODE, bit 0 ==1 and the last action block is loaded in the main run after block
search. Alarm 10208 is then activated as a function of the NC/PLC interface signal DB3200 DBX1.6 (PLC action
finished).
- Search alarm 10208 has been suppressed by the PI service _N_FINDBL (third decade of the parameter supplied
with "2"). Alarm 10209 is set as a function of whether or not a search ASUB has been configured (MD11450
$MN_SEARCH_RUN_MODE bit 1) with the end of the search ASUB or the loading of the last action block in the main
run.
Reaction:
Interpreter stop
NC Stop on alarm.
96
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual

Advertisement

Table of Contents
loading

Table of Contents