SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
20308
[Channel %1: ] Manual traverse in the SZS coodinate system is not possible
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
Manual traverse in the SZS coodinate system is not possible in JOG Retract mode.
Reaction:
Alarm display.
Remedy:
Deselect JOG Retract with RESET
Program
Clear alarm with the Delete key or NC START.
Continuation:
20310
[Channel %1: ] Axis %2 traverse to the specified position is not possible
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The displayed axis cannot be traversed to the entered position in JOG Retract mode.
It is limited to the interrupt position when JOG Retract was selected.
Reaction:
Alarm display.
Remedy:
Traverse within the permitted positions
Program
Clear alarm with the Delete key or NC START.
Continuation:
21550
[Channel %1: ] Axis %2 Travel from hardware limit switch not possible. Reason: %3
Parameters:
%1 = Channel number
%2 = Axis name
%3 = Cause
Definitions:
It has been tried to retract a following axis of an axis coupling or an output axis of a transformation through the master
axis or input axis of a transformation. This is not permitted in the current situation.
Possible reasons:
1 No permissible direction of retraction
2 Coupling not synchronous
3 Retraction not permitted for the active coupling
4 Reserved
5 Retraction not permitted for the active transformation
Reaction:
NC Start disable in this channel.
Alarm display.
Remedy:
Remedy for error cause:
1 Define another travel direction
2 Deactivate the coupling and travel the axis/axes separately
3 Deactivate the coupling and travel the axis/axes separately
4 Reserved
5 Deactivate the transformation and travel the axis/axes separately
Program
Clear alarm with the RESET key. Restart part program
Continuation:
21600
Monitoring for ESR active
Definitions:
-
Reaction:
NC not ready.
Alarm display.
All alarm responses are delayed by one IPO cycle.
Remedy:
The display can be suppressed with MD 11410 $MN_SUPPRESS_ALARM_MASK Bit 16 = 1
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
292
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1