Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 341

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
380076
PROFIBUS/PROFINET: No DO1 message frame: Bus %2 slave/device %1
Parameters:
%1 = Slave/device address
%2 = Number of the affected bus
Definitions:
Note for the system setup engineer: A PROFIBUS slave/PROFINET device used as an NCK drive does not have a
valid DO1 message frame assignment (see MD13120 $MN_CONTROL_UNIT_LOGIC_ADDRESS with the STEP 7
configuration).
This alarm is indicating, among other things, that the alarm time-of-day synchronization is not working between the
controller and this slave/device.
Reaction:
Alarm display.
Remedy:
Enter a valid value in MD13120 $MN_CONTROL_UNIT_LOGIC_ADDRESS.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
380077
PROFIBUS/PROFINET: Too many DOs: Currently minimum %2, maximum %3 in DO
group %1
Parameters:
%1 = DO group
%2 = Current number of DOs
%3 = Maximum permissible number of DOs
Definitions:
Note for the system setup engineer: The number of equivalent DOs ("drive objects" group) on all busses (configured
and connected) exceeds predefined limit values.
The services linked to these DOs (e.g. time synchronization, alarm display, HMI diagnostics, HMI data archiving) can
no longer be guaranteed for all DOs in this group.
The following different DO groups exist (see parameter %1):
0 = Device (CU, DO1)
1 = Communications (CU-LINK)
2 = Drive (SERVO, VECTOR)
3 = Infeed (ALM etc.)
4 = Terminal block (TB)
5 = Terminal module (TM)
Reaction:
Alarm display.
Remedy:
Reduce the number of devices (containing DOs of this type) on the bus.
Use a more powerful type of controller (one which supports more DOs).
Program
Switch control OFF - ON.
Continuation:
380500
PROFIBUS/PROFINET: Fault on drive %1, code %2, value %3, time %4
Parameters:
%1 = Axis
%2 = Fault code of drive (P947(/945)/P824)
%3 = Fault value of drive ((P949/P826)
%4 = Fault time of drive (P948/P825)
Definitions:
Contents of fault memory of assigned drive.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
380501
PROFIBUS/PROFINET: Fault on bus, slave/device, DO ID %1, code %2, value %3, time
%4
Parameters:
%1 = 8 bit bus number, 8 bit slave/device number, 16 bit DO ID
%2 = Fault code of drive (P947)
%3 = Fault value of the drive (P949)
%4 = Fault time of the drive (P948)
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.3 Drive alarms
341