[Channel %1: ] Block %2 combine OSCILL and POSP during oscillation with
infeedmotion
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When oscillating controlled by synchronized actions, the assignment of oscillating and infeed axis (OSCILL) as well
as the definition of the infeed (POSP) must be carried out in one NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14033
[Channel %1: ] Block %2 involute: no end point programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No end point was programmed for the involute. This is either possible via direct programming with the geometry axis
identifiers or by specifying the angle between start and end vector.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14034
[Channel %1: ] Block %2 involute: angle of rotation too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With programming of the angle of rotation (with AR) for involute interpolation, the maximum programmable angle of
rotation is limited if the involute is moving towards the basic circle. The maximum value is reached if the involute
touches the basic circle. With MD21016 $MC_INVOLUTE_AUTO_ANGLE_LIMIT = TRUE, each angle is accepted
without an alarm; if necessary, the angle is automatically limited during interpolation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14035
[Channel %1: ] Block %2 involute: start point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the start point of the involute must be outside the basic circle. The programmed center point
or radius must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14036
[Channel %1: ] Block %2 involute: end point invalid
Parameters:
%1 = Channel number
%2 = Block number, label