14065
[channel %1: ] block %2 error in SPRINT/ISOPRINT command: error code %4
information %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Additional information
%4 = Error code
Definitions:
When interpreting the SPRINT or ISOPRINT command, an error was detected which was described in more detail by
parameter %4. Parameter %3 may supply additional information on the incurring problem.
List of error codes (parameter %4):
1: invalid format description %3 recognized
2: Format %.nP: overrange when converting into 32 bit number
3: Format %P: Character %3 cannot be converted with the code selected by MD 10750 /
$MN_SPRINT_FORMAT_P_CODE.
4: Maximum string length of 400 bytes exceeded
5: SPRINT/ISOPRINT command programmed with an invalid number of parameters
6: SPRINT/ISOPRINT parameters programmed with impermissible data type
7: Format %m.nP: overrange due to parameter n with MD 10751 / $MN_SPRINT_FORMAT_P_DECIMAL = 0
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct SPRINT and/or ISOPRINT command(s).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14066
[channel %1: ] block %2 error when outputting to external device on command %3,
error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Part program command
%4 = Error code
Definitions:
When processing the commands ISOOPEN, ISOPRINT, ISOCLOSE or EXTOPEN, WRITE, EXTCLOSE, an error
was detected which is described in detail by the error code.
List of error codes:
1: external device cannot be opened
2: external device is not configured
3: external device configured with invalid path
4: no access rights for external device
5: external device already exclusively assigned
6: external device already assigned in shared mode
7: file length greater than LOCAL_DRIVE_MAX_FILESIZE
8: maximum number of external devices exceeded
9: option not set for LOCAL_DRIVE
11: V24 already occupied by Easy-Message function
12: Append/Overwrite specification is inconsistent with extdev.ini
14: external device not assigned or opened
15: error when writing to external device
16: invalid external path programmed
21: error when closing external device
22: external device not installed (mounted)
90: Timeout
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correcting the parameterization of the ISOCLOSE, ISOPRINT or ISOCLOSE command. See also MD 10830
$MN_EXTERN_PRINT_DEVICE and MD 10831 $MN_EXTERN_PRINT_MODE.
Check the configuration of the external device on the CF card in /user/sinumerik/nck/extdev.ini and /oem/sinumerik/
nck/extdev.ini.
Check the connection and functioning of the external device.
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms