SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
- Error code 13 : DB380x DBX5006.2 (Spindle start counterclockwise rotation;
- Error code 14 : DB380x DBX5006.4 (Spindle positioning).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Resolve the conflict, for example by deactivating transformation prior to spindle start.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22292
[Channel %1: ] Changeover of the operating mode of the axis/spindle %2 using PI
service not possible, Cause %3
Parameters:
%1 = Channel number
%2 = Axis/spindle
%3 = Cause
Definitions:
It is not possible to change over the operating mode of the axis/spindle.
Cause:
1: The required axis/spindle is not known in the channel.
2: The required axis/spindle is not available in the channel.
3: The required axis/spindle is defined as virtual axis.
4: The required axis is not defined as spindle. Therefore, it is not possible to change over the operating mode of the
axis.
5: The required axis/spindle is a permanently assigned PLC axis/spindle.
6: The required axis/spindle is an active slave axis/spindle.
7: Spindle operation is not possible for transformed spindle/axis.
8: The required axis/spindle is not available as command axis.
Reaction:
Alarm display.
Remedy:
1: Please select the PI service again.
2: Please select the PI service again.
3: Reset MD 30132 IS_VIRTUAL_AX.
4: When required, configure axis as spindle.
5: Axis/spindle enabled by the PLC.
6: Deactivate coupling of the slave axis/spindle.
7: Deactivate transformation.
8: Wait until the axis is again available.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22295
[Channel %1: ] Spindle %2 DBB30 function not possible (cause: error code %3)
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Error code
Definitions:
The function request by PLC via DBB30 interface could not be executed. The cause is specified by the error code.
Error codes:
- Error code 1 : internal use
- Error code 2 : internal use
- Error code 3 : internal use
- Error code 4 : internal use
- Error code 5 : Switchover to command axis not possible
- Error code 6 : Switchover to PLC axis not possible
- Error code 20 : internal use
- Error code 21 : internal use
- Error code 22 : internal use
- Error code 23 : MD 30132 IS_VIRTUAL_AX has been set
- Error code 50 : internal use
- Error code 51 : internal use
- Error code 70 : internal use
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
308