13: Slave axis grouping 3
Program
Switch control OFF - ON.
Continuation:
10652
[Channel %1: ] Axis %2 gantry warning threshold exceeded
Parameters:
%1 = Channel number
%2 = Axis
Definitions:
The gantry following axis has exceeded the warning limit specified in MD37110
$MA_GANTRY_POS_TOL_WARNING.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
1. Check axis (uneven mechanical movement?)
2. MD not set correctly (MD37110 $MA_GANTRY_POS_TOL_WARNING). Changes to this MD take effect after a
RESET.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10653
[Channel %1: ] Axis %2 gantry error threshold exceeded
Parameters:
%1 = Channel number
%2 = Axis
Definitions:
The gantry following axis has exceeded the error limit (actual value tolerance) specified in MD37120
$MA_GANTRY_POS_TOL_ERROR.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
1. Check axis (uneven mechanical movement?)
2. MD not set correctly (MD37120 $MA_GANTRY_POS_TOL_ERROR). A POWER ON is necessary after modifying
the MD.
If the axes are not yet referenced, MD37130 $MA_GANTRY_POS_TOL_REF is the trigger condition for the error
message.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10654
[Channel %1: ] Waiting for synchronization start of gantry group %2
Parameters:
%1 = Channel number
%2 = Gantry unit
Definitions:
The alarm message appears when the axes are ready for synchronization. The gantry grouping can now be
synchronized. The actual value difference between the master and slave axes is greater than the gantry warning limit
MD 37110 $MA_GANTRY_POS_TOL_WARNING. The synchronization must be started explicitly with the NC/PLC
interface signal DB380x DBX5005.4 (Start gantry synchronization).
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
See Function Manual, Special Functions, Gantry Axes (G1)
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10655
[Channel %1: ] Synchronization of gantry group %2 in progress
Parameters:
%1 = Channel number
%2 = Gantry unit
Definitions:
The alarm may be suppressed with MD37150 $MA_GANTRY_FUNCTION_MASK Bit2 = 1.
Reaction:
Alarm display.
Remedy:
--
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms