Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 264

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
17502
[Channel %1: ] Block %2 indexing axis %3 with Hirth tooth system stop is delayed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
For the indexing axis, the 'Hirth tooth system' function is activated and the override has been set to 0 or another stop
condition (e.g. VDI interface signal) is active. Since it is possible to stop only on indexing axes, the next possible
indexing position is approached. The alarm is displayed until this position is reached or the stop condition is
deactivated.
Reaction:
Alarm display.
Remedy:
Wait until the next possible indexing position is reached or set override > 0 or deactivate another stop condition.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
17503
[Channel %1: ] Block %2 indexing axis %3 with Hirth tooth system and axis not
referenced
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
The 'Hirth tooth system' function is activated for the indexing axis and the axis is to be traversed although it is not
referenced.
Reaction:
Alarm display.
Remedy:
Reference axis.
Program
Clear alarm with the Delete key or NC START.
Continuation:
17505
[Channel %1: ] Block %2 motion synchronous action: %3 indexing axis %4 is active
with Hirth tooth system
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Axis name
Definitions:
The 'Hirth tooth system' function is activated for the indexing axis. This axis can therefore approach only indexing
positions, another travel movement of the axis is not possible.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Correct part program.
Correct FC16 or FC18 call.
Deselect machine data MD30505 $MA_HIRTH_IS_ACTIVE.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
17510
[Channel %1: ] Block %2 invalid index for indexing axis %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The programmed index for the indexing axis is beyond the position table range.
Example:
Perform an absolute approach of the 56th position in the list allocated via the axis-specific MD30500
$MA_INDEX_AX_ASSIGN_POS_TAB with the 1st positioning axis, the number of positions is e.g. only 40 (MD10900
$MN_INDEX_AX_LENGTH_POS_TAB_1 = 40).
N100 G.. U=CAC (56)
Or, with equidistant distances, the programmed index is smaller or equal 0.