SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program or machine data.
Only with active "OEM transformation" compile cycle:
Reference the axes included in the transformation before selecting transformation.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14410
[Channel %1: ] Block %2 spline active at geometry axis changeover
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It is not allowed to change the assignment of geometry axes to channel axes in a spline curve definition.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14411
[Channel %1: ] Block %2 tool radius compensation active at geometry axis changeover
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It is not permissible to change the assignment of geometry axes to channel axes when tool radius compensation is
active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14412
[Channel %1: ] Block %2 transformation active at geometry axis changeover
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It is not permissible to change the assignment of geometry axes to channel axes when transformation is active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14414
[Channel %1: ] Block %2 GEOAX function: incorrect call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameters for calling the GEOAX(...) are incorrect. Possible causes:
- Uneven number of parameters.
- More than 6 parameters were specified.
- A geometry axis number was programmed which was less than 0 or greater than 3.
- A geometry axis number was programmed more than once.
- An axis identifier was programmed more than once.
- An attempt was made to assign a channel axis to a geometry axis which has the same name as one of the channel
axes.
- An attempt was made to assign a channel axis to a geometry axis lacking IPO functionality (see MD30460
$MA_BASE_FUNCTION_MASK, Bit8).