Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 171

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Definitions:
In a subroutine call the programmed number of passes P is zero or negative.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program number of passes between 1 and 9 999.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14014
[Channel %1: ] Selected program %3 not available or will be edited
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
The selected parts program is not in the NCK memory or the access authorization for the program selection is from a
higher level than the current control status.
During creation, this program received the protection level of the NC control which was active at the time.
In SW 5 or higher a program edited on HMI can no longer be started with NC Start.
The alarm will also be issued, if a file other than the specified definition file has been selected for the GUD or macro
definition.
Reaction:
Alarm display.
Remedy:
Reload the program in the NCK memory or check and correct the name of the directory (workpiece overview) and the
program (program overview) and reselect.
Program
Clear alarm with the Delete key or NC START.
Continuation:
14015
[Channel %1: ] Block %2 program %3 is not enabled
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
The execution right currently set in the control (e.g. key switch position 0) is inadequate to execute part program %3.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Raise the execution right to match the protection level of part program %3
- Assign a lower protection level to part program %3 or release (key switch protection level 0)
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14016
[Channel %1: ] Block %2 error when calling the subroutine via M/T function
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following conflict was detected in a subprogram call per M or T function:
In the block referenced by parameter %2:
- An M or T function replacement has already been activated
- A modal subprogram call is active
- A subprogram return jump is programmed
- An end of program is programmed
- An M98 subprogram call is active (only in external language mode)
- T function replacement by D function programming in the same part program line is not possible with active TLC
(G43/G44) in ISO2 system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
An M or T function replacement is only possible if a subprogram call or return jump has not already been performed
as a result of other program constructs. The part program must be corrected accordingly.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms