Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 167

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Remedy:
- correct ISOPRINT command
- within an ISOPRINT command, only format instructions of the same type %m.nP or %.nP may be applied
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12770
[Channel %1: ] Block %2 Conversion not possible. Error code %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cause of the error
Definitions:
When converting a part program using the G code converter function, an error was identified.
- Error cause: 1 = no Jobshop program. Conversion is only permissible for Jobshop -programs
-
be converted was transferred
-
-
$MC_GCODE_RESET_VALUES[46])
-
program was deleted.
Reaction:
Alarm display.
No alarm reaction.
Remedy:
Do not activate G code converter in the ISO mode
Program
Clear alarm with the Delete key or NC START.
Continuation:
14000
[Channel %1: ] Block %2 illegal end of file
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm 14000 is output in the following situations:
- Parts program was not terminated with M30, M02 or M17.
- Executing from external: Download was canceled (e.g. because HMI was switched off).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- End parts program with M30, M02 or M17 and start parts program.
- Executing from external: If the download for the selected program was canceled,
the default program _N_MPF0 is automatically selected with RESET
The selection of the user program must be repeated after that.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14001
[Channel %1: ] Block %2 illegal end of block
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
After system-internal data manipulation (e.g. when reloading from an external source) a part file can end without
having LF as the last character.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Read out the part program, modify it with a text editor (e.g., insert blanks or comments before the displayed block), so
that after reading it in again the part program has a different structure in the memory.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
2 = an LUD call by reference variable as transfer parameter at a predefined function or a cycle that cannot
3 = G code conversion is not possible in the AUTO mode
4 = an attempt was made to make a conversion in the ISO mode, (check G291,
5 = for the output into the trace program, sufficient memory was no longer available, therefore the trace