SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
For the definition the MD 20090 $MC_SPIND_DEF_MASTER_SPIND is available for the default or the keyword
SETMS in the part program, thus allowing each spindle of the channel to be redefined as master spindle.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Preset the master spindle with MD20090 $MC_SPIND_DEF_MASTER_SPIND[n]=m (n ... channel index, m ... spindel
no.) or define it with an identifier in an NC part program before a G function that requires a master spindle is
programmed.
The machine axis that is to be operated as a spindle must be equipped in MD35000
$MA_SPIND_ASSIGN_TO_MACHAX[n]=m (n ... machine axis index, m ... spindle no.) with a spindle number.
Additionally, the MD20070 $MC_AXCONF_MACHAX_USED[n]=m (n ... channel axis index, m ... machine axis index)
must be used to assign it to a channel (channel axis index 1 or 2).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10820
[Channel %1: ] Rotary axis/spindle %2 not defined
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
Revolutional feed has been programmed for contouring and synchronous axes or for an axis/spindle. However, the
rotary axis/spindle from which the feed is to be deduced is not available.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Correct part program or set the SD43300 $SA_ASSIGN_FEED_PER_REV_SOURCE correctly.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10860
[Channel %1: ] Block %2 feedrate not programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Cause:
A traversing velocity has not been programmed for the displayed traversing block.
Feed F or FZ:
With the traversing velocity defined by feed F or FZ, F or FZ was not reprogrammed after the feed type changed, for
example linear feed G94 after revolutional feedrate G95 F or G95 FZ.
Modal feed FRCM:
With modal traversing velocity FRCM defined for rounding RND or chamfering CHF, feed FRCM was not
reprogrammed after the feed type changed, for example linear feed G94 after revolutional feedrate G95, or
revolutional feedrate G95 F after tooth feedrate G95 FZ.
Note:
Feed FRCM also has to be reprogrammed when the feed type changes if the current traversing block does not contain
chamfering CHF or rounding RND, but the feed FRCM was programmed active, that is unequal to 0, before the feed
type changed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Program feedrate in accordance with the interpolation type.
- G93: The feedrate is specified as a time-reciprocal value under address F in [rev/min].
- G94 and G97: The feedrate is programmed under address F in [mm/min] or [m/min].
- G95: The feedrate is programmed as revolutional feedrate under address F in [mm/revolution]
or under the address FZ in [mm/tooth].
- G96: The feedrate is programmed as cutting rate under address S in [m/min]. It is derived from the current spindle
speed.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
124
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual