SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Set valid machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4343
[Channel %1: ] Attempt made to change the machine data of an active transformation.
Parameters:
%1 = Channel number
Definitions:
An attempt was made to change the machine data of an active transformation and to activate the machine data with
RESET or NEWCONFIG.
Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Set valid machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4344
[Channel %1: ] Block %2 Axis %3 defined in $NK_NAME[%4] is not available in the
current channel
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
%4 = Index of the chain element
Definitions:
In the specified chain element a machine axis was indicated that is not available in the current channel on
transformation selection. This means that this axis is currently assigned to another channel.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Specify the axis available in the channel.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4346
[Channel %1: ] Invalid geoaxis assignment in machine data %2[%3]
Parameters:
%1 = Channel number
%2 = Name of machine data
%3 = Transformation number
Definitions:
MD2.... $MC_TRAFO_GEOAX_ASSIGN_TAB_... contains an invalid entry. The following causes for the error are
possible:
- The entry references a channel axis which does not exist.
- The entry is zero (no axis) but the transformation needs the relevant axis as a geometry axis.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Correct the entry in MD2.... $MC_TRAFO_GEOAX_ASSIGN_TAB_ or MD2.... $MC_TRAFO_AXES_IN_.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4347
[Channel %1: ] Invalid channel axis assignment in machine data %2[%3]
Parameters:
%1 = Channel number
%2 = Name of machine data
%3 = Transformation number
76
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1