Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 382

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.5 Cycle alarms
61296
[Channel %1: ] Block %2: Blank programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The blank has been programmed incorrectly.
Remedy:
Correct the blank.
61297
[Channel %1: ] Block %2: Reference for incremental retraction plane missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The retraction plane can only be specified in increments if the blank is entered.
Remedy:
Program the retraction plane in absolute terms.
61298
[Channel %1: ] Block %2: No work offset entered for main spindle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No work offset has been specified for the main spindle.
Remedy:
Specify a work offset for the main spindle in the program header or under Settings.
61299
[Channel %1: ] Block %2: No work offset entered for counterspindle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No work offset has been entered for the counterspindle.
Remedy:
Specify a work offset for the counterspindle in the program header or under Settings.
61300
[Channel %1: ] Block %2: Probe defective
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Remedy:
61301
[Channel %1: ] Block %2: Probe not switching
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring distance was completely traversed, but no switching signal was generated at the measuring input.
Remedy:
-Check measuring input.
-Check measuring distance.
-Probe defective.
61302
[Channel %1: ] Block %2: Probe - collision
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring probe collided with an obstacle when being positioned.
Remedy:
- Check spigot diameter (may be too small)
- Check measuring distance (may be too long)
61303
[Channel %1: ] Block %2: Safety margin exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring result differs greatly from the specified value.
382