Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 156

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
12553
[Channel %1: ] Block %2 name %3 option/function is not active
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The option (if MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 1) or the NC function (if MD10711
$MN_NC_LANGUAGE_CONFIGURATION = 3)
related to this language command is not active.
But the name of the language command is known.
Each programming of this language command is rejected with this alarm.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the "Compensation block" function by pressing the PROGRAM CORRECT softkey.
The cursor positions itself on the incorrect block.
- Correct the name used (in the case of a typing error).
- Activate the NC function (if a language command of an inactive function has been programmed).
- Enable the option required (if a language command of a function with a non-enabled option has been programmed).
See also MD10711 $MN_NC_LANGUAGE_CONFIGURATION.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12554
[Channel %1: ] Block %2 replacement cycle %3 for the predefined procedure is
missing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cycle name
Definitions:
The replacement cycle that is to be called instead of the predefined procedure
is not present / unknown in the control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC stop key and select the "Compensation block" function by pressing the PROGRAM CORRECT softkey.
The cursor will position itself in the faulty block.
- Correct the name used for the predefined procedure (write error)
- Or load the replacement cycle into one of the cycle directories (+ restart)
- Or set the machine data bit for the predefined procedure in MD11754 $MN_COUPLE_CYCLE_MASK to 0 so that
the predefined procedure is executed again.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12555
[Channel %1: ] Block %2 function not available (identification %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Definitions:
The identifier has not been defined for this system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC stop key and select the "Compensation block" function by pressing the "Program correct" softkey. The
correction indicator will position in the incorrect block.
- Correct the name used (write error)
- Use a better software system in case of malfunction
- Check the definition of variables, subroutines and macros
- Declare a subroutine with EXTERNAL; load the subroutine to SPF-Dir
- Check the interface definition of the subroutine
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
156
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual

Advertisement

Table of Contents
loading

Table of Contents