SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Remedy:
Please inform the authorized personnel/service department.
For retrofitting the option, please refer to your machine manufacturer or to a sales representative of SIEMENS AG,
A&D MC.
Program
Clear alarm with the Delete key or NC START.
Continuation:
8041
Axis %1: MD %2 reset, corresponding option not sufficient
Parameters:
%1 = Axis number
%2 = String: MD identifier
Definitions:
All of the axes selected in the machine data of the assigned option are used. Safety functions have been selected for
too many axes in the axial machine data.
The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
--
Program
Switch control OFF - ON.
Continuation:
8044
Option for IPO cycle time %1 ms not set
Parameters:
%1 = Impermissible IPO cycle time
Definitions:
The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
- Option-free >= 8ms
- 1. 1st step >= 6ms
- 2. 2nd step >= 4ms
- 3. 3rd step >= 2ms
- 4. 4th step <2ms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Increase IPO cycle time (e.g. via MD10070 $MN_IPO_SYSCLOCK_TIME_RATIO)
Program
Switch control OFF - ON.
Continuation:
8045
'Activation drive integrated ESR' option not set
Definitions:
'Extended stop and retract (ESR)' was activated in the drive, although the corresponding option was not set.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Purchase option
- Deactivate 'Extended stop and retract (ESR)' function in the drive.
Program
Switch control OFF - ON.
Continuation:
92
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1