Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 58

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Definitions:
Only axes that have been activated in the channel by MD20070 $MC_AXCONF_MACHAX_USED [kx]=m may be
declared as geometry axes, transformation axes or orientation axes in MD20050
$MC_AXCONF_GEOAX_ASSIGN_TAB [gx]=k. This also applies to MD22420 $MC_FGROUP_DEFAULT_AXES
(gx: Geometry axis index, kx: Channel axis index, k: Channel axis no., m: Machine axis no.).
Assignment of geometry axes to channel axes
MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB (includes channel axis no. k):
- Geometry axis index: 0, 1st channel: 1, 2nd channel: 1
- Geometry axis index: 1, 1st channel: 2, 2nd channel: 0
- Geometry axis index: 2, 1st channel: 3, 2nd channel: 3
MD20070 $MC_AXCONF_MACHAX_USED (includes machine axis no. m):
- Channel axis index: 0, 1st channel: 1, 2nd channel: 4
- Channel axis index: 1, 1st channel: 2, 2nd channel: 5
- Channel axis index: 2, 1st channel: 3, 2nd channel: 6
- Channel axis index: 3, 1st channel: 7, 2nd channel: 0
- Channel axis index: 4, 1st channel: 8, 2nd channel: 0
- Channel axis index: 5, 1st channel: 0, 2nd channel: 0
- Channel axis index: 6, 1st channel: 0, 2nd channel: 0
- Channel axis index: 7, 1st channel: 0, 2nd channel: 0
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Correct
- MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB
- MD24... $MC_TRAFO_AXES_IN_...
- MD24... $MC_TRAFO_GEOAX_ASSIGN_TAB_...
- MD22420 $MC_FGROUP_DEFAULT_AXES
- and/or MD20070 $MC_AXCONF_MACHAX_USED.
Program
Switch control OFF - ON.
Continuation:
4004
[Channel %1: ] Machine data %2 axis %3 defined repeatedly as geometry axis
Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = Axis index
Definitions:
An axis may only be defined once as a geometry axis.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Correct MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Program
Switch control OFF - ON.
Continuation:
4005
[Channel %1: ] Maximum number of axes is exceeded. Limit %2
Parameters:
%1 = Channel number
%2 = Upper limit for the number of axes in the channel
Definitions:
MD20070 $MC_AXCONF_MACHAX_USED defines which machine axes can be used in this channel. This
simultaneously defines the number of active axes in the channel. This upper limit has been exceeded. Note: The
channel axis gaps may cause certain indices of MD20070 $MC_AXCONF_MACHAX_USED to remain unused and
therefore do not count as active channel axes.
58
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
Diagnostics Manual

Advertisement

Table of Contents
loading