NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The errors listed above must be corrected in the subroutine for the stock removal contour.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10932
[Channel %1: ] Block %2 preparation of contour has been restarted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The first contour preparation/contour decoding run must be terminated with EXECUTE.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the keyword EXECUTE to terminate the contour preparation in the part program before again calling up
contour segmentation (keyword CONTPRON).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10933
[Channel %1: ] Block %2 contour programm does not contain enough contour blocks
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The contour program contains:
- Less than 3 contour blocks with CONTPRON
- No contour blocks with CONTDCON
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Increase the size of the program with the stock removal contour to include at least 3 NC blocks with movements in
both axes of the current machining plane.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10934
[Channel %1: ] Block %2 array for contour segmentation is set too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During contour segmentation (activated with the keyword CONTPRON), the field for the contour table has been
detected as too small. For every permissible contour element (circle or straight line) there must be a row in the contour
table.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Base the definition of the field variables of the contour table on the contour elements to be expected. The contour
segmentation divides some NC blocks into as many as 3 machining cuts. Example: N100 DEF TABNAME_1 [30, 11]
Field variables for the contour table provide for 30 machining cuts. The number of columns (11) is a fixed quantity.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10950
[Channel %1: ] Calculation of arc length function too inaccurate
Parameters:
%1 = Channel number
Diagnostics Manual