Alarm display.
Remedy:
Check tool call in the NC part program:
- Correct tool number T.. programmed?
- Tool parameters P1 - P25 defined? The dimensions of the tool edge must have been entered previously either
through the operator panel or through the V.24 interface.
Description of the system variables $P_DP x [n, m]
n ... Associated tool number T
m ... Tool edge number D
x ... Parameter number P
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17191
[Channel %1: ] Block %2 T= %3 not existing, program %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number or T identifier
%4 = Program name
Definitions:
A tool identifier which the NCK does not recognize was programmed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
If the program pointer is at an NC block which contains the specified T identifier: If the program is incorrect, remedy
the error with a correction block and continue the program. If the data block is missing, create one. You can do this by
downloading a data block with all the defined D numbers onto the NCK (via MMC with overstore) and continue the
program.
If the program pointer is at an NC block which does not contain the specified T identifier: The error occurred at an
earlier point in the program where the T command appeared, but the alarm was not output until the change command
was detected.
If the program is incorrect - T5 programmed instead of T55 - the current block can be corrected with a correction block;
i.e. if only M06 is entered, you can correct the block with T55 M06. The incorrect T5 line remains in the program until
it is terminated by a RESET or end of program.
In complex program structures with indirect programming, it may not be possible to correct the program. In this case,
you can only intervene locally with an overstore block - with T55 in the example. If the data block is missing, create
one. You can do this by downloading the data block of the tool with all the defined D numbers onto the NCK (via MMC
with overstore), program the T command with overstore, and continue the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17194
[Channel %1: ] Block %2 no suitable tool found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- An attempt was made to access a tool which has not been defined.
- The specified tool does not permit access.
- A tool with the desired properties is not available.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check access to tool:
- Are the parameters of the command correctly programmed?
- Does the status of the tool prevent access?
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17195
[Channel %1: ] block %2 illegal tool holder number %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Tool holder number