Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 225

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

16010
[Channel %1: ] Block %2 machining stop after lift fast
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
LIFTFAST without interrupt routine (ASUB) has been programmed. The channel is stopped after the lift motion has
been carried out.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
After the channel stop, the axes must be retracted manually in JOG and the program canceled with Reset.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16015
[Channel %1: ] Block %2 wrong axis identifier %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
Axis names from different coordinate systems were used to program axes for LIFTFAST. The retraction movement is
no longer clear.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Use axis names from one coordinate system.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16016
[Channel %1: ] Block %2 no retraction position programmed for axis %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
The retraction enable was programmed for LIFTFAST without defining a retraction position for the axis. The retraction
movement is no longer clear.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program a retraction position for the relevant axis.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16017
[Channel %1: ] Axis %2 Identifier %3, LIFTFAST ignores this axis, current axis not
capable of retraction
Parameters:
%1 = Channel
%2 = Axis, spindle
%3 = Identifier
Definitions:
LIFTFAST cannot be applied to the axis.
Alarm can be suppressed via MD11415 $MN_SUPPRESS_ALARM_MASK_2 bit 11.
Identifiier (parameter 3) is bit-coded and displays some possible causes for the alarm:
0x01Axis is in another channel
0x02Axis is in spindle mode (e.g. SPOS)
0x04Axis is PLC axis
0x08Axis is oscillating axis
0x10Axis is neutral axis
0x20Axis is coupled slave axis
0x40Axis is in static synchronized action