Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 205

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Definitions:
A maximum of 5 auxiliary functions of type "M" may be entered in an NC block. The upper limit is the total of
programmed and implicitely generated M auxiliary functions. Implicit auxiliary functions M19 and M70 are generated,
if in MD35035 $MA_SPIND_FUNCTION_MASK, bit 19 has been set for M19 and/or bit 20 for M70. M19 is generated
with SPOS and SPOSA depending on the configuration. The same applies to M70 and transition into axis operation.
The address extension corresponds to the spindle number like it is output to the PLC.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Distribute the M auxiliary functions and spindle functions that implicitely generate M19 and M70 to several blocks.
- Deactivate any implicit auxiliary functions that are not required in MD35035 $MA_SPIND_FUNCTION_MASK, bit 19
and/or bit 20.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14770
[Channel %1: ] Block %2 auxiliary function programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The permissible number of programmed auxiliary functions per NC block has been exceeded or more than one
auxiliary function of the same auxiliary function group has been programmed (M and S function).
In the user-defined auxiliary functions, the maximum number of auxiliary functions per group in the NCK system
settings has been defined for all auxiliary functions by means of the MD11100
$MN_AUXFU_MAXNUM_GROUP_ASSIGN (default: 1)
For each user-defined auxiliary function to be assigned to a group, the assignment is effected through 4 channel-
specific machine data.
Return jump from asynchronous subprogram with M02/M17/M30, whereby the M code is not alone in the block. This
is impermissible if the asynchronous subprogram interrupts a block with WAITE, WAITM or WAITMC. Remedy:
Program M02/M17/M30 alone in the block or replace via RET.
22010 AUXFU_ASSIGN_TYPE: type of auxiliary function, e.g. M
22000 AUXFU_ASSIGN_GROUP: required group
22020 AUXFU_ASSIGN_EXTENSION: any required extension
22030 AUXFU_ASSIGN_VALUE: function value
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program - max. 16 auxiliary functions, max. 5 M functions per NC block, max. 1 auxiliary function per
group.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14780
[Channel %1: ] Block %2 unreleased option used (identification %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Definitions:
A non-released option has been used in the block.
Identifier Brief description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
LaserCtrl option
ClearCtrl option
FeedAdapt option
AaTOff option
Tang option
LeadCtab option
ELG option
Trafo5 option
Traoem option
Transmit option
Tracon option
Tracyl option
Traang option
Oscill option
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
205

Advertisement

Table of Contents
loading