Siemens SINUMERIK 808D ADVANCED Diagnostic Manual page 63

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Definitions:
Renaming of an NC code was not possible for one of the following reasons:
- The old identifier does not exist
- The new identifier lies in another type range.
NC codes/keywords can be reconfigured via machine data as long as the type range is not abandoned.
Type 1: "real" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: settable addresses: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Correct MD10712 $MN_NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified.
Following odd address: New identifier
e.g.: $MN_NC_USER_CODE_CONF_NAME_TAB [10] = "ROT"
$MN_NC_USER_CODE_CONF_NAME_TAB [11] = " "
clears the ROT function from the control
Program
Switch control OFF - ON.
Continuation:
4060
Standard machine data loaded (%1, %2, %3, %4)
Parameters:
%1 = Identifier 1
%2 = Identifier 2
%3 = Identifier 3
%4 = Identifier 4
Definitions:
The standard MD were loaded because
- a cold start was requested or
- the MD buffer voltage failed or
- an initialization was requested for loading the standard machine data (MD11200 $MN_INIT_MD).
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. After automatically loading the standard MDs, the
individual MDs must be entered or loaded in the relevant system.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4062
Backup data loaded
Definitions:
The user data saved in the flash memory are loaded to the SRAM.
Reaction:
Alarm display.
Remedy:
Load specific machine data again.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4065
Buffered memory was restored from backup medium (potential loss of data!)
Definitions:
The user data of the NC and the retentive data of the PLC are stored in a buffered memory area (SRAM). A possible
inconsistency was detected in this buffered memory during ramp-up of the control.
The buffered memory was initialized with the last backup copy. Changes that have been made since the last update
of the backup copy in the buffered memory were thus lost.
A possible reason for a data inconsistency could be that the backup time was exceeded. Please note the required ON
time of the control specified in your commissioning guide.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Diagnostics Manual
Diagnostics Manual, 08/2013, 6FC5398-6DP10-0BA1
SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
63

Advertisement

Table of Contents
loading

Table of Contents