SINUMERIK 808D ADVANCED alarms
3.2 NCK alarms
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Set machine date MD11351 $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Program
Switch control OFF - ON.
Continuation:
4641
Invalid handwheel input for handwheel %1
Parameters:
%1 = Handwheel input
Definitions:
For ETHERNET only:
The handwheel input for handwheel %1 requested through MD11352 $MN_HANDWHEEL_INPUT is not available for
ETHERNET handwheels. A maximum of 6 handwheels can be configured.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure MD11352 $MN_HANDWHEEL_INPUT for a valid input for the corresponding handwheel
Program
Switch control OFF - ON.
Continuation:
5000
Communication job not executable %1
Parameters:
%1 = Reference to which resources are no longer available.
Definitions:
The communication job (data exchange between NCK and HMI, e.g.: loading an NC part program) cannot be executed
because there is insufficient memory space. Cause: too many communication jobs in parallel.
Reaction:
Alarm display.
Remedy:
- Reduce the number of communication jobs taking place at the same time or increase MD10134
$MN_MM_NUM_MMC_UNITS
- Restart communication job.
Please inform the authorized personnel/service department. No remedial measures are possible - the operation
triggering the alarm message has to be repeated. Clear the alarm display with Cancel.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6000
Memory reorganized using standard machine data
Definitions:
The memory management was not able to allocate the NC user memory with the values in the machine data. It did
not have enough memory available because the total memory available is provided as dynamic and static memory for
the NC user (e.g. for macro definitions, user variables, number of tool offsets, number of directories and files etc.).
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Redefine the NC memory structure!
A specific MD for NC user memory allocation cannot be stated to be the cause of the alarm. The MD initiating the alarm
therefore has to be determined on the basis of the default values in the machine data by changing the user-specific
memory structure step by step.
Usually, it is not just one single MD that has been set too large. Therefore it is advisable to reduce the memory area
by a certain proportion in several MDs.
Program
Restart part program.Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Continuation:
6010
[Channel %1: ] Data block %2 not or not completely created, error code %3
Parameters:
%1 = Channel number
%2 = String (block name)
%3 = Internal error code